Design af en omskiftende strømforsyning til enfaset og trefaset strømforsyning
Valg af PWM-kredsløb
Artiklen vælger UC3846 dobbelt udgangsstrøm type PWM controller IC. Dette kredsløb har en *maksimal* arbejdscyklus på 50% ved en koblingsfrekvens på 20KHZ, så dens styring er effektiv og stabil.
IGBT-drev og beskyttelse
IGBT work is controlled by the positive and negative gate voltage, when UGE>0, IGBT til, når UGE<0, (general UGS ≤ -5V), IGBT cut-off. Taking into account its characteristics and operating principle, the choice of positive and negative dual power supply M57962L-type special drive integrated circuit. The circuit has a built-in timing logic short-circuit protection circuit, and has a protection delay function. Driver protection principle circuit shown in Figure 3 (b). In addition to the IGBT drive circuit itself to provide short-circuit (overcurrent) protection, in parallel with the IGBT RC buffer branch and power supply parallel absorption capacitors on both sides of the method is also effective.
Konklusion
Denne skiftende strømforsyning er mere velegnet til praktiske applikationer. Fordi parameterdesignet af ensretterkredsløbet er baseret på enkeltfasede overvejelser, når det bruges i trefaset strømforsyning har tilstrækkelig margin, så systemet er mere stabilt og pålideligt; brugt i enfaset strømforsyning kan også fungere normalt. Dette løser selvmodsigelsen ved at skifte strømforsyning på grund af strømforsyningsbegrænsninger. Med denne metode kan den eksisterende koblingsstrømforsyning også omdannes til en enfaset, trefaset koblingsstrømforsyning kan forsynes.