Weighing sensors are widely used in industrial weighing (such as belt scales, weighbridge scales, electronic scales, human scales, etc.), force detection, and tension pressure measurement. The general faults of the weighing sensor during on-site use are as follows.
1. The sensor is overloaded, and the user and manufacturer did not communicate clearly. The sensor range and actual force value, as well as the weight size, do not match, resulting in sensor overload and deformation of the sensor bridge arm resistance, causing circuit imbalance. The sensor cannot function properly, the output signal fluctuates, and there are phenomena such as infinite resistance.
2. Den sensor bly er trækket fra hinanden, og brugeren gjorde ikke tage beskyttende foranstaltninger under brug. Den sensor bly er normalt trækket fra hinanden at den sensor bly grænseflade, som påvirker sensoren's reagerer ikke eller pludselig ændrer i måling værdier. 3. Forkert brug af sensorer, statisk sensorer der har alvorlig skade sådan som påvirkning, forskydning, og torsion under brug, gør dem ikke kan være repareret.
1. The sensor manufacturer provides sensor output sensitivity and power supply voltage at the factory, and we detect the sensor output signal based on these two parameters. The strain gauge type weighing force sensor outputs an analog signal millivolt voltage. For example, the sensor output sensitivity is 2.0mV/V, and the power supply voltage is DC10V. Two parameters can provide us with a linear relationship between the sensor excitation working voltage and the required DC10V. The sensor output signal corresponds to a 2.0mV output per 1V excitation voltage. For example, if the full scale of the sensor is 50KG, then the full scale output of the sensor is 20mV with a DC10V voltage. Based on this relationship, we use a multimeter mV gear to measure the sensor output signal. The no-load output of the sensor is normal at 0mV, which is greater than this value, but when it approaches this value, a change in value indicates that the sensor has zero drift. If the value is large, it indicates that the sensor is damaged or the internal bridge is a circuit, and the bridge arm resistance is asymmetric.
2. Bestem om sensor stamme måler er er beskadiget baseret på sensor parametre leveret af fabrikken, input modstand, og output modstand. Det input og output modstand værdier af sensorer variere fra producent til producent. Så dette behov til at testes ifølge til producenten's mærkning. Brug a multimeter til mål den modstand mellem den strøm forsyning og jord, som godt som modstand mellem den signal ledning og jord. Hvis modstand værdi er er højere end fabrikken værdien, it angiver at den sensor har været overbelastet og stammen sporvidde har deformeret. hvis modstand værdi er er uendelig, stammen sporvidde af sensoren er alvorligt beskadiget og kanikke berettes repareres.
3. På grund af til den hyppige brud af ledninger under brugen af sensorer% 2c mens det ydre lag af kappen ledning er intakt% 2c vi visuelt inspicere integriteten af sensoren ledningen. Vi bruger den ohmiske rækkevidde af et multimeter til detekter kontinuitet af sensoren ledningen. Hvis modstanden er den er bestemt til brud% 2c modstanden ændringer% 2c den kontakt er dårlig.